Answer

Feb 21, 2025 - 01:55 AM
To install the DOYMA UGA BKD 150 System Cap with sleeve in collar technology, please follow the steps below:
1. Ensure that you have the correct size of the system cap for your pipe or cable. Refer to the "Product" section of the manual and find the appropriate article number based on the outer diameter of your pipe or cable.
2. Prepare the existing flange sleeve or on-wall flange sealing collar where you want to connect the system cap. Make sure the surface is clean and free from any debris or contaminants.
3. Insert the system cap into the flange sleeve or collar, aligning the bayonet closure with the corresponding slots or grooves. Press the system cap firmly to ensure a tight fit.
4. Once the system cap is securely in place, check for any gaps or openings. The system cap should provide a gas and watertight seal. If necessary, adjust the position or tighten the bayonet closure to eliminate any gaps.
5. If you need to connect a cable protection pipe using collar technology, insert the pipe into the system cap's sleeve. Make sure the pipe is inserted fully and securely.
6. After installation, perform a visual inspection to ensure that the system cap is properly installed and sealed. Check for any signs of leakage or misalignment.
Please note that the DOYMA UGA BKD 150 System Cap is compatible with other established systems, making it versatile for various applications. For specific details and technical specifications, refer to the manual provided with the product.
Add New Comment