Answer
Feb 20, 2025 - 10:54 PM
Installation of the ABH Manufacturing Inc 4 Inch Removable Electrified Continuous Hinge Section involves the following steps:
1. Begin by specifying the wire configuration when ordering the product. The template for installation remains the same regardless of the wire configuration chosen.
2. Ensure compatibility with the electrified hardware manufacturer by specifying it during the ordering process.
3. The hinge section requires a frame with a 90° opening for proper installation.
4. Refer to the "Wire Transfer View" provided in the manual for guidance on connecting the wires.
5. The product uses a single conductor #22 AWG miniature hook-up wire for applications requiring extreme flexibility.
6. The conductor is made of #22 AWG 168/44 (0.002") soft bare copper LHL.
7. The insulation is made of a proprietary formulation PVC with a 0.010" nominal wall that meets VW-1 flame requirements.
8. The wire has a diameter of 0.053" ± 0.003" and a resistance of 16.7 ohms max. at 20°C per 1000 ft.
9. The voltage rating of the wire is 600 volts RMS, depending on the specification.
10. The product is available as RoHS compliant.
For more detailed installation instructions and diagrams, please refer to the instruction manual provided by ABH Manufacturing Inc. You can visit their website at www.abhmtg.com or contact them via email at abhinfo@abhmfg.com for further assistance.