Answer

Feb 19, 2025 - 05:47 AM
To install the , follow these steps:
1. Ensure that the main power in your facility is turned off before installation.
2. Connect the AC Input cable to a socket near the Electrical Box to power on the Power Clamp according to the corresponding phase wiring diagram.
3. Attach both ends of the Current Transformer Cables to the power clamp. Spin the waterproof latch clockwise until both ends are tightened and secured.
4. Open the clamp and apply it to the electric meter cable. Ensure that the arrow on the clamp faces the correct direction of the electricity current flow (P1 ➔ P2). If the arrow faces the reverse direction, the reading meter will display 0.
Important safety information:
- The power clamp must be installed and serviced only by a qualified electrical personnel.
- Do not touch the terminals of the device during testing.
- Turn off all power supply for this equipment before installing.
- Make sure that the power supply is off before connecting or disconnecting it to an auxiliary device.
- Always use a properly rated voltage sensing device to confirm power is off.
- Replace all devices, doors, and covers before applying power to the equipment.
Please refer to the user guide for more detailed instructions and safety precautions.
Add New Comment