Answer

Feb 19, 2025 - 03:11 AM
To wire the EMX ULT-DIN DIN Rail Mount Vehicle Loop Detector, follow the instructions provided in the manual. The wiring connections are as follows:
- Terminal Pin 1: Shield - Earth Ground
- Terminal Pin 2: Loop Connection
- Terminal Pin 3: Loop Connection
- Terminal Pin 4: Power (12-24 VDC/AC)
- Terminal Pin 5: Power (12-24 VDC/AC)
- Terminal Pin 6: No Connection
- Terminal Pin 7: Output B - NO (normally open contact)
- Terminal Pin 8: Output B - COM (common contact)
- Terminal Pin 9: No Connection
- Terminal Pin 10: Output A - NC (normally closed contact)
- Terminal Pin 11: Output A - COM (common contact)
- Terminal Pin 12: Output A - NO (normally open contact)
Make sure to comply with all applicable codes and safety regulations while wiring the detector. For more detailed information, refer to the "Wiring Connections" section in the instruction manual.