To choose the right tip for your B&G Primeline Sprayer, you need to consider the type of valve selected. The User Guide Addendum for your specific valve will provide more information on changing and choosing tips. The most common tips and their flow rates at 20 psi / 1.38 bar are listed in the User Manual. Here are some examples:
- 50° Coarse Fan: Flow rate of 14.1 oz/min or 417.0 ml/min
- 80° Fine Fan: Flow rate of 6.4 oz/min or 189.3 ml/min
- Large Pin Stream: Flow rate of 8.9 oz/min or 263.2 ml/min
- Small Pin Stream: Flow rate of 4.5 oz/min or 133.16 ml/min
- Crack & Crevice Straw (red): Flow rate of 6 oz/min or 177.4 ml/min
- Crack & Crevice Straw (white): Flow rate of 3.8 oz/min or 112.4 ml/min
Always calibrate the sprayer for the specific formulation you are using. The User Manual Addendum provides more details on flow rates for different tips.