After installing the KNOP KK901 Cheek Plug, it is important to test the product to ensure it is functioning properly. Here are the steps to test the KK901:
1. Make sure the staff has an alarm device/receiver that is compatible with the KK901. Refer to the user manual of the receivers used for instructions on how to set them up.
2. Position one person to activate the KK901 by turning their head towards it, as described in the manual.
3. Another person should systematically walk around the area while the KK901 is activated and make a sketch of the building and the areas where there is protection. This sketch should be placed in the office for reference.
4. The staff member with the alarm device/receiver should receive an alarm when the KK901 is activated. This confirms that the transmission is working properly.
5. If the transmission fails, the KK901 will light up red and repeat the transmission up to two times at 30-second intervals.
By following these steps, you can ensure that the KNOP KK901 Cheek Plug is functioning correctly and can provide the necessary alarms when needed.