To install the ROBUS RCM9030AS-04, RCM9040AS-04 COSMIC 90W LED Flood Light, please follow these steps:
1. Ensure that the mains supply is switched off before starting the installation.
2. Choose a suitable location for the luminaire and mark the wall with appropriate fixing positions. Before drilling, make sure that the hole does not interfere with any pipes, cables, or other building services.
3. Attach the luminaire and fix the bracket by tightening the screws. Adjust the luminaire to the desired angle and ensure that it is securely fixed.
4. The luminaire is supplied with 1m of rubber cable. Using a suitable IP rated enclosure, terminate the Brown wire (Live), Blue wire (Neutral), and Green/Yellow wire (Earth) to the switch supply.
5. This product does not have any user-serviceable parts. If any part is damaged, disconnect it from the mains and discontinue use.
6. Please note that no fixing screws are provided, so make sure to use appropriate fixing screws.
7. The recommended projection distance for this floodlight is 7.5m, with a maximum width of 14-17m. The mounting height should be between 5.5m and 8m.
It is important to consult a qualified electrician for the installation to ensure safety and compliance with electrical regulations.