Proper installation of the ActronAir SCG260E COMMERCIAL Split Ducted Unit is essential for its correct operation and safe use. Here are the steps to follow for installation:
1. Read the installation guide: Before starting the installation process, carefully read the installation guide provided with the unit. This guide contains important information and specifications specific to your split ducted indoor unit.
2. Inspect the unit: Upon receiving your shipment, check the unit, components, and accessories for any signs of damage. If there is any damage, contact ActronAir Customer Care Department immediately to obtain a Goods Return Number.
3. Comply with codes and regulations: The installer is responsible for ensuring that the unit installation complies with the relevant council, state/federal codes, regulations, and building code standards. All electrical wiring must be in accordance with current electrical authority regulations.
4. Follow safety instructions: Follow all safety instructions provided in the manual. Only licensed HVAC technicians should install and service the air conditioning equipment. Ensure proper safety precautions are taken, such as turning off the power from the main isolator before proceeding with any service work and wearing appropriate personal protective equipment (PPE).
5. Determine the location: The unit is intended for indoor installation only. It is recommended to mount the unit in the roof cavity, ensuring a stable and rigid support with proper weight distribution. Consider the minimum service access clearances provided in the unit drawings.
6. Condensate and safety tray drainage: The unit comes with an integrated safety drain tray to reduce the potential of condensate damage to the roof. Ensure proper installation of the condensate drain, following the provided instructions.
7. Supply and return air ducts: The indoor unit is supplied with duct flanges for easy connection to the system's ductwork. Ensure that the supply and return air ducts are adequately sized to meet the system's airflow and static pressure requirements. Use flexible duct connections where noise and vibration are a concern.
8. Install return air filters: Place air filters in the return air side of the unit to maintain efficiency and prolong operation. Ensure the filters are easily accessible for service and maintenance.
9. Follow field pipe and electrical connections: Follow the installation and connection requirements for field pipes and electrical wiring as specified in the installation and commissioning guide of the outdoor unit that matches your indoor unit. All electrical work must be performed by a licensed electrician.
10. Lift the unit safely: If crane lifting is required, follow the recommended lifting procedures and adhere to WH&S regulations for safe and secure lifting practices. If using a forklift, insert the fork tines through the unit feet assembly, avoiding the electrical panel end.
11. Commission the fan: Depending on the model, follow the instructions provided in the manual to properly commission the standard or EC indoor fan.
12. Perform regular maintenance: Regular servicing of the unit by a qualified technician is recommended every 12 months for residential applications and every quarter for commercial applications. Follow the maintenance frequency checklist provided in the manual.
Please note that this answer provides a general overview of the installation process. For detailed and specific instructions, refer to the ActronAir SCG260E COMMERCIAL Split Ducted Unit Installation Guide provided with the product.