To install the GARNET 815-UHP-H Spillstop Ultra Alarm Controller with Hose Protection, follow these steps:
1. Choose a suitable location for mounting the controller on the trailer. Ensure that it is easily visible and protected from direct road spray or damage.
2. Mount the display enclosure using the provided mounting flange holes. Use spacers to shim the enclosure away from the mounting surface to allow for water drainage. It is important to prevent water from freezing behind the enclosure, as this can cause damage.
3. Connect the wiring according to the applicable wiring diagram provided by Garnet. Use soldered connections or secure crimp connectors for all connections. Avoid using spade connectors, as they may degrade over time.
4. Use a cable such as 7 conductor Scully cable or similar for the wiring. Use a strain relief where the cable enters the enclosure to create a weatherproof seal. You can use a junction box available from Garnet to simplify the wiring.
5. Program the alarm points in the gauge (808P2 or 810PS2 SEE LEVEL gauge). Set alarm #1 as the shutdown point beyond which loading is not permitted. Set alarm #2 as the horn alarm point. Set alarm #3 as the reset point when the tank is considered empty. Set alarm #4 just above alarm #1. Refer to the gauge's manual for programming details.
6. Put the cover back on the SPILLSTOP controller and test the system for proper operation by lifting the float. Verify that the horn sounds and the pump stops at the horn alarm point. Pressing the bypass button should silence the horn and restart the pump. The pump should shut down at the shutdown alarm point. Pressing and holding the override button should sound the horn and allow the pump to restart. Ensure that the bypass is removed when the float is at least one inch above the bottom of the tank.
Please note that this is a summary of the installation process. For complete and detailed instructions, refer to the GARNET 815-UHP-H Spillstop Ultra Alarm Controller with Hose Protection User Manual.