To install the legrand WNRL10 Radiant Single Pole Universal Wall Switch, follow these steps:
1. Turn off power to the device at the circuit breaker.
2. Flip the existing light switch multiple times to confirm that the power is off. Make sure the power is off to all devices in the electrical box.
3. Remove the existing device.
4. Check for the following wires:
- HOT or LINE: Receives power from the circuit box. Do not touch or let the "hot" wire contact other wires.
- LOAD: Directs power to your light(s).
- NEUTRAL: Creates a path to return current to the power source when the device is off. Required for your switch installation.
- GROUND: Provides a safe path for electricity in the event of a short circuit.
5. Use the wire nuts provided to secure the wires together.
6. Connect the WHITE neutral wire on the switch to the neutral wires in the box, using the red wire nut.
7. Connect the LOAD wire on the switch to the load wire(s) in the box.
8. Connect the HOT wire on the switch to the hot wire(s) in the box.
9. Connect the GREEN ground wire on the switch to the ground wire(s) in the box.
10. Fold the wires into the electrical box, taking care not to pinch a wire.
11. Use the included screws to secure the smart switch to the electrical box. Do not fully tighten the screws.
12. Turn the power back on at the circuit breaker and test the smart switch by pressing the switch to turn the light on/off.
Please note that this is a general overview of the installation process. For more detailed instructions and safety precautions, refer to the legrand WNRL10 Radiant Single Pole Universal Wall Switch Instruction Manual.