Answer

Feb 14, 2025 - 09:14 PM
To connect the UMG 96 RM-EL Digital Rack Mount Meter to the power supply, follow these steps:
1. Before connecting the supply voltage, check if the voltage and frequency correspond to the details on the rating plate. Ensure that the limit values stipulated in the user manual have been complied with.
2. In building installations, protect the supply voltage with a UL/IEC approved circuit breaker or a fuse.
3. Install the device in a weather-protected front panel on switching cabinets. The cut-out size should be 92+0.8 x 92+0.8 mm.
4. Ensure adequate ventilation for the device. Install the device vertically and adhere to clearances from neighboring components.
5. Connect the supply voltage to the device. The supply voltage level is specified on the rating plate. After connecting the supply voltage, check if an indication is shown on the display. If no display appears, check if the supply voltage is within the rated voltage range.
6. Before starting any work, make sure to render the system free of voltage and check that the system is free of electrical energy.
Please refer to the instruction manual for more detailed information and safety instructions on connecting the UMG 96 RM-EL Digital Rack Mount Meter to the power supply.