Answer

Feb 13, 2025 - 11:53 PM
To install the ROBUS RCM12530AS COSMIC 125W Cool Asymmetric LED Flood Light, please follow these steps:
1. Ensure that the mains supply is switched off before starting the installation.
2. Select a suitable location for the luminaire.
3. Mark the wall with appropriate fixing positions. Before drilling, make sure that the hole does not interfere with any pipe work, cables, or other building services.
4. Attach the luminaire and fix the bracket by tightening the screws. Then, adjust it to the desired angle and ensure that it is secure.
5. The luminaire is supplied with 1m of rubber cable. Using a suitable IP rated enclosure, terminate the Brown (Live), Blue (Neutral), and Green/Yellow (Earth) wires according to the wiring regulations in your country.
6. Before carrying out any insulation resistance testing, make sure to disconnect the luminaire.
7. If any part of the luminaire is damaged, disconnect it from the mains and discontinue its use.
8. Please note that no fixing screws are provided, so you will need to use appropriate fixing screws for installation.
It is important to have the installation carried out by a qualified electrician to ensure safety and compliance with electrical regulations. For more detailed instructions and safety information, please refer to the instruction manual provided with the product.