Answer
![manuals.plus](https://data3.answerbase.com/answerbase/15673/UserFiles/User3627018/profileImage3627018.jpg?638365818380000000)
Feb 11, 2025 - 04:19 AM
To set the DMX address for the ACME Stage Blinder IP, follow these steps:
1. Press the MENU button on the rear panel of the fixture until the DMX 512 Address Setting option is displayed on the screen.
2. Press the ENTER button to select the DMX 512 Address Setting option. The display will start blinking.
3. Use the DOWN and UP buttons to change the DMX address value. The range is from 001 to 512.
4. Once you have selected the desired DMX address, press the ENTER button to set it. The fixture will now respond to the new DMX address.
5. If you want to exit the menu mode without making any changes, press the MENU button.
Please note that the DMX address should be set according to the DMX universe and channel configuration of your DMX controller. Make sure to set a unique address for each fixture to avoid conflicts.
Add New Comment![Sending...](https://manuals.answerbase.com/images/loading-boxes.gif)