Answer

Feb 10, 2025 - 10:57 PM
Before installing the FADINI APROLI 280 Batt External Oil-Hydraulic Operator with Articulated Arm, it is important to assess the suitability of the access, its general condition, and the structure. Make sure there is no risk of impact, crushing, shearing, conveying, cutting, entangling, and lifting situations that may jeopardize people's safety. Avoid installing near any source of heat and flammable substances.
Here are the general steps for installation:
1. Verify the presence of a thermal-magnetic circuit breaker upstream the installation.
2. Use appropriate objects to test the correct functionality of safety accessories such as photocells and sensitive edges.
3. Carry out a risk analysis by measuring the crushing and impact force of the main opening and closing edge.
4. Identify the appropriate solution to eliminate and reduce risks.
5. If the gate to automate is equipped with a pedestrian entrance, prepare the system to prohibit the operation of the engine when the pedestrian entrance is used.
6. Apply safety nameplates with CE marking on the gate to warn about the presence of the installation.
7. Inform and instruct the end user about the proper use of the system by providing a technical dossier.
It is important to note that all installation operations must be performed by a qualified technician in compliance with safety regulations. For detailed instructions and diagrams, please refer to the FADINI APROLI 280 Batt External Oil-Hydraulic Operator with Articulated Arm Instruction Manual.
Add New Comment