Answer

Feb 09, 2025 - 10:38 PM
There are two alternative ways to connect to or set the device’s management IP address: using the pre-set management IP address or connecting a monitor and keyboard to the server.
1. Using the Pre-Set Management IP Address:
- Connect a PC directly to the device’s management port using an Ethernet cable.
- Set the PC’s IP address to 10.0.20.100 and the subnet mask to 255.255.0.0.
- Open a web browser and enter the IP address 10.0.20.101 to access the web user interface.
2. Connecting Monitor and Keyboard to the VB440-Appliance:
- Connect a monitor and keyboard directly to the server.
- Login to Linux using the default credentials: username "root" and password "mpeg101".
- Use the nmtui tool to edit the network connections and set the appropriate network settings.
- Save and quit nmtui, then reboot the server using the "reboot" command.
- Once the server reboots, the web user interface can be accessed using the IP address that was set for the management port.
Note: For more detailed instructions and additional configuration options, please refer to the full user manual of the Sencore VB440-Appliance.