To connect the MOKA SFX S-1000Strobe LED Strobe Wash Outdoor Moving Light to AC power, follow these steps:
1. Ensure that the fixture is powered off and unplugged before connecting it to AC power.
2. The fixture can operate on any 100-240V, 50/60Hz AC mains power supply.
3. For permanent installation, have a qualified electrician wire the mains cable directly to a suitable branch circuit. Make sure the junction's ingress protection (IP) rating is suitable for the location.
4. For temporary installation, the mains cable may be fitted with a grounded connector intended for exterior use.
5. When installing standard type C circuit breakers, there are limitations on the number of fixtures that can be connected. Make sure not to exceed the following:
- 4 fixtures connected through the same type C, 10A circuit breaker.
- 7 fixtures connected through the same type C, 16A circuit breaker.
6. The fixture must be grounded/earthed and be able to be isolated from AC power.
7. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
8. After connecting the fixture to power, run the onboard test using the "FixtureText" menu to ensure that the fixture and each LED are functioning correctly.
Please refer to the "Connecting AC Power" section in the user manual for more detailed instructions and safety precautions.