Answer

Feb 07, 2025 - 09:15 PM
To connect the LP gas tank to the ELEMENTI OFG410LP METEORA Fire Table, please follow these steps:
1. Make sure the gas supply system is turned to "OFF".
2. Place the tank seat on the ground and place a 20 lb. propane tank into the tank seat.
3. Tighten down the xxxx on the side of the tank seat to secure the propane tank.
4. Check to make sure there is no debris in the head of the LP gas tank or in the head of the regulator valve.
5. Connect the gas line to the tank by turning the xxxx clockwise. Hand tighten only.
6. Perform a leak check by making a leak check solution using 1 part dishwashing soap and 3 parts water in a spray bottle.
7. Spray the leak check solution on the valve connections, paying particular attention to the areas indicated by arrows.
8. If any bubbles appear, turn the LP gas tank OFF, reconnect, and re-test. If bubbles continue to appear, disconnect the LP gas source and contact ELEMENTI for technical support.
9. If no bubbles appear after one minute, turn the tank OFF, wipe away the solution, and proceed.
Please refer to the owner's manual for additional safety information and precautions.