To install the BubblyNet s-op-c12-drwh Trimless Occupancy Sensor, follow these steps:
1. Cut a hole with a diameter of 63.5 mm (2.5 inches) in the desired location for the sensor.
2. Install the mud ring as shown in Figure 2. Use fiberglass tape on the edges of the perforated sheet. Secure the mud ring with four nails in the holes of the perforated sheet.
3. Place a cardboard to cover the hole of the fixture. Apply mudding material over the perforated sheet and around the trim collar. Sand and finish as required (Figure 3).
4. Pull out the female connector from the ceiling (Figure 4).
5. Connect the sensor's male connector to the female connector (Figure 5).
6. Insert the sensor into the trim opening, ensuring that the wires are all the way in (Figure 5).
7. After completing step 5, the installation should resemble Figure 6.
Please note that the fixture must be installed by a qualified electrician. Disconnect power at the electrical panel before servicing. Also, ensure that materials used for ceiling fixation conform to the relevant building regulations.
For further assistance or inquiries, you can contact BubblyNet at:
- Phone: 727.316.5319
- Fax: 727.683.9720
- Website: www.bubblynet.com
Remember to retain the instruction manual for maintenance reference. The manufacturer reserves the right to change or modify the design, dimensions, and specifications without notice.