The maximum drain-source voltage (VDS) for the VISHAY IRLZ44 Power Mosfet is 60V. This means that the voltage between the drain and source terminals should not exceed 60V to avoid damaging the device.
The gate-source voltage (VGS) has two limits. The positive limit is +10V, and the negative limit is -10V. These limits indicate the maximum voltage that can be applied between the gate and source terminals.
It is important to note that exceeding these voltage limits can cause permanent damage to the Power Mosfet. Therefore, it is crucial to ensure that the applied voltages are within the specified limits to ensure safe and reliable operation.