To set the temperature on the Pegler Yorkshire TRV MRV with Integrated Terrier Pushfit Connections, follow these steps:
1. Initially, set the TRV to the desired room temperature from the provided table in the instruction manual. For example, set it to Position 3/20°.
2. Leave the TRV for at least one hour to allow the temperature to stabilize.
3. If you want a higher or lower room temperature, simply adjust the setting accordingly and repeat the process.
Note: The TRV settings are factory calibrated, but they may vary slightly depending on the installation.
Question: How can I fix the thermal head at a set temperature or limit the range of operation?
Answer: The Pegler Yorkshire TRV MRV with Integrated Terrier Pushfit Connections has the facility to fix the thermal head at a set temperature or limit the range of operation. Here's how:
1. To fix a set temperature, locate a peg in the slot on either side of the selected setting and push it home.
2. To set a limited range for temperature control, first, locate a peg in the slot to the right of the viewing window for the lowest temperature setting required.
3. Adjust the valve head to display the maximum temperature desired.
4. Locate a peg in the slot to the left side of the viewing window.
5. Push both pegs home.
6. The head will now be adjustable between the selected range of temperatures.
Question: How can I turn on the frost protection feature on the TRV?
Answer: If you plan to be away from home for an extended period, you can turn on the frost protection setting on the Pegler Yorkshire TRV MRV with Integrated Terrier Pushfit Connections. Here's how:
1. Set the TRV to the frost protection setting "*", which can be found on the temperature scale.
2. If the temperature falls below 7°C, the valve will automatically open to provide protection against freezing. This is provided that the boiler remains in operation via a frost slot.
Note: The frost protection feature is useful when you are away from home to prevent freezing of the radiator and pipes.
Question: How do I remove the radiator with the TRV installed?
Answer: To remove the radiator with the Pegler Yorkshire TRV MRV with Integrated Terrier Pushfit Connections installed, follow these steps:
1. Set the TRV to the "O" position, which is the positive "Off" position.
2. This will enable you to remove the radiator for maintenance purposes.
3. To avoid accidental operation of the valve or damage while decorating, you can use the manual shut-off cap instead of the TRV head.
4. In this case, remove the TRV sensor head by unscrewing the securing ring and replace it with the manual cap before removing the radiator.
Note: Make sure to follow proper safety precautions and consult a professional if needed when removing or working on radiators.