Answer
![manuals.plus](https://data3.answerbase.com/answerbase/15673/UserFiles/User3627018/profileImage3627018.jpg?638365818380000000)
Jan 31, 2025 - 10:04 PM
To connect and power the StarTech com IES1G52UP12V 5 Port Unmanaged Industrial-Grade Switch, please follow these steps:
1. Grounding the Switch:
- Connect a grounding wire to the grounding point on the switch and to the earth ground connection.
2. Connect the Power Sources:
- Connecting and installing the terminal block must be completed by a licensed electrician.
- Turn off the power source before connecting the power wire to the terminal block.
- Connect the power wires from a DC power source (12-56V DC) or the provided barrel power connector adapter to the terminal block connectors on the switch. Connect the positive wire to V+ and the negative wire to V-.
- Secure the wires by tightening the screws in the terminal block with a flat head screwdriver.
- Optionally, repeat step 2 to add a redundant power source.
3. Select the Default Function and Speed using the DIP Switches:
- Toggle the DIP switches up and/or down to select the SFP Slot F5 (Right) or T5 Network Port. When SFP Slot F5 is selected, the T5 Network Port will be disabled, and vice versa. The DIP switches can also be used to select the network speed.
4. Connecting the Switch:
- DIP Switch Set to F5:
- Insert two MSA-Compliant SFP Transceiver Modules (sold separately) into the SFP Slots F5 and F6 on the switch.
- Connect a fiber optic cable (sold separately) to the fiber optic ports on each of the SFP modules and to the fiber-network devices.
- DIP Switch Set to T5:
- Connect a network cable to the network device and to the T5 PoE Port or any PoE Port on the switch.
Please refer to the provided user guide for more detailed instructions and illustrations.