Answer

Jan 31, 2025 - 05:25 AM
To connect the DYN-I-9000 Triaxial MEMS Gyroscopes to a power supply, you will need to follow the cable code/pin configuration provided in the manual. The general sensor connector configuration is as follows:
For Differential Mode:
- Red: V + Power supply voltage +6 to +20 VDC
- Black: Ground Power GND
- X-Axis: Yellow (+), Purple (-)
- Y-Axis: Blue (+), Green (-)
- Z-Axis: White (+), Orange (-)
For Single-Ended Mode:
- Red: V + Power supply voltage +5 V to +20 VDC
- Black: Ground Power GND
- RX: Brown (X-Axis)
- RY: Grey (Y-Axis)
- RZ: Pink (Z-Axis)
- White-Brown: NC (Not connected)
It is important to note that you should never connect the power supply and/or power ground to any other cables. Always use a clean power source and check the voltage range.
For further information and visual representation, please refer to the "Operation and Installation" section in the instruction manual provided.
Add New Comment