Answer

Jan 31, 2025 - 02:26 AM
To connect the accelerometers to a power supply, follow these steps:
1. Identify the cable code/pin configuration:
- Red: V + Power supply voltage +6 to +20 VDC
- Black: Ground Power GND
- X-Axis: Yellow (Signal +) and Purple (Signal -)
- Y-Axis: Blue (Signal +) and Green (Signal -)
- Z-Axis: White (Signal +) and Orange (Signal -)
2. Make sure to never connect the power supply and/or power ground to the signal cables (yellow, purple, blue, green, white, and orange). It is important to use a clean power source and check the voltage range.
3. Connect the red cable to the positive terminal of the power supply and the black cable to the ground terminal.
4. Connect the signal cables (yellow, purple, blue, green, white, and orange) to the appropriate channels or data acquisition system according to the desired axis.
Please refer to the "Operation and Installation" section of the DYN-C-3000-DE Triaxial Capacitive Accelerometers User Manual for more detailed instructions and illustrations.
Add New Comment