To connect the DYN-C-3000-LN triaxial capacitive accelerometers to a power supply, follow these steps:
1. Identify the cable code/pin configuration:
- Red: V+ Power supply voltage +5 to +20 VDC
- Black: Ground Power GND
- X-Axis: Yellow: Signal(+) Positive, analog output voltage signal for differential mode.
- Purple: Signal(-) Negative, analog output voltage signal for differential mode.
- Y-Axis: Blue: Signal(+) Positive, analog output voltage signal for differential mode.
- Y-Axis: Blue: Signal(+) Positive, analog output voltage signal for differential mode.
- Z-Axis: White: Signal(+) Positive, analog output voltage signal for differential mode.
- Orange: Signal(-) Negative, analog output voltage signal for differential mode.
2. Make sure to never connect the power supply and/or the power ground to the colored cables (yellow, purple, blue, green, white, and/or orange). Also, never connect the power supply to the power ground.
3. Connect the power supply voltage (+5 to +20 VDC) to the red cable.
4. Connect the ground power (GND) to the black cable.
5. Connect the analog output voltage signals for differential mode (X-axis, Y-axis, and Z-axis) to their respective colored cables.
6. Ensure that you are using a clean power source within the specified voltage range.
Please refer to the "Operation and Installation" section of the user manual for more detailed instructions and illustrations.