Answer

Jan 31, 2025 - 01:58 AM
To connect the DYN-C-3000-SE Triaxial Capacitive Accelerometers to a power supply, follow these steps:
1. Identify the cable code/pin configuration:
- Red: V+ Power supply voltage +6 to +20 VDC
- Black: Ground Power GND
- X-Axis: Yellow: Signal Analog output voltage signal for single-ended
- Y-Axis: Blue: Signal Analog output voltage signal for single-ended
- Z-Axis: White: Signal Analog output voltage signal for single-ended
2. Make sure to never connect the power supply and/or power ground to the yellow, blue, and/or white cables. Also, never connect the power supply to the power ground.
3. Connect the V+ power supply voltage to the red cable and the ground power GND to the black cable. Ensure that you use a clean power source and check the voltage range.
By following these steps, you can properly connect the DYN-C-3000-SE Triaxial Capacitive Accelerometers to a power supply. For further information or troubleshooting, please refer to the product manual or contact a Dynalabs engineer.