Answer

Jan 31, 2025 - 01:55 AM
To connect the DYN-C-1000-LN accelerometer to a power supply, follow these steps:
1. Identify the cable code/pin configuration:
- Red: V+ Power supply voltage (+5 to +20 VDC)
- Black: Ground Power GND
- X: Yellow: Signal(+) Positive, analog output voltage signal for differential mode.
- Blue: Signal(-) Negative, analog output voltage signal for differential mode.
2. Make sure to never connect the power supply and/or power ground to the yellow and/or blue cables. Also, never connect the power supply to the power ground.
3. Use a clean power source within the voltage range specified (between +5 to +20 VDC).
By following these steps, you can safely connect the DYN-C-1000-LN accelerometer to a power supply for operation. For further assistance or clarification, please refer to the product manual or contact a Dynalabs engineer at the provided phone number or email address.