To change the timer settings on the GNB LAB ALL505881 ALLELUX Xmax UV LED Lamp, follow these steps:
1. Connect the lamp to the power supply.
2. Press the timer button to turn on the lamp.
3. Choose one of the available timer options: 30s, 60s, 90s, or 120s. You can also start the lamp without selecting a time by putting your hand into the device, and the irradiation will start automatically when motion is detected by the sensor (exposure limit is 120s).
4. If you want to enable the time saving function on the 30s, 60s, or 90s timer buttons, press and hold the button for about 2 seconds to set the function. To clear the memory, press and hold the button for 2 seconds again or press another timer button.
5. By default, the lamp power is set to 54W. If you want to change the power, press and hold the 120s timer button for 2 seconds. Then, press and hold the timer button for 2 seconds again to return the power to 54W.
6. The display will show the remaining exposure time. When using the 30s, 60s, or 90s timer, it will count down. When using the 120s timer and starting the device using the motion sensor, it will count up.
7. Follow the curing instructions for the specific product you are using.
8. After using the lamp, disconnect it from the power source.
Please note that it is important to read and follow all the warnings and precautions mentioned in the user manual to ensure safe and proper usage of the lamp.