To adjust the sensing range of the Oras 943484 Electra Washbasin faucet, follow these steps:
1. Remove the control-box cover.
2. Push the button located inside the control box.
3. Position a piece of white paper vertically in front of the faucet at the desired distance for the photocell to react (e.g., at the outer edge of the washbasin).
4. Hold the paper at this distance, and water will start to flow after about 30 seconds.
5. Once the water flow has stopped, pull the paper away.
6. The sensing range is now set and stored in the faucet's memory.
7. If the distance is unsatisfactory, you can readjust it by changing the position of the piece of paper.
8. Finally, replace the control-box cover.
Please note that the factory preset for the sensing range should be suitable for most installations. Adjusting the sensing range should only be necessary if you have specific requirements or if the faucet is not activating properly.