Answer
Jan 26, 2025 - 11:03 PM
To install the WB50-FG Flush Mount Box for AUDAC Wallpanel in a Gypsum wall, please follow the steps below:
1. Begin by measuring and marking the desired location for the flush mount box on the Gypsum wall. Ensure that the location is suitable for the wall control panel's operation and accessibility.
2. Use the provided cut-out measurement of 135 x 75 mm to mark the dimensions of the opening on the Gypsum wall. Double-check the measurements to ensure accuracy.
3. Using a suitable cutting tool, carefully cut along the marked lines to create the opening for the flush mount box. Take caution to avoid damaging any electrical wiring or other components within the wall.
4. Once the opening is created, insert the WB50-FG Flush Mount Box into the opening. Ensure that it fits securely and aligns properly with the wall surface.
5. Secure the flush mount box in place by using screws or other appropriate fasteners. Refer to the installation manual for specific instructions on securing the box.
6. After the flush mount box is securely installed, you can proceed to mount the AUDAC wall control panel, such as the DW5066, MWX65, or WP523, onto the flush mount box. Follow the instructions provided with the specific wall control panel for proper mounting procedures.
7. Make sure to connect any necessary wiring or cables to the wall control panel according to the panel's instructions and any applicable electrical codes.
8. Finally, test the functionality of the wall control panel to ensure it is working correctly. If any issues arise, refer to the user manual or contact AUDAC customer support for further assistance.
Please note that this answer is a general guide, and it is always recommended to refer to the specific product's manual for detailed installation instructions and safety guidelines.