Answer
![manuals.plus](https://data3.answerbase.com/answerbase/15673/UserFiles/User3627018/profileImage3627018.jpg?638365818380000000)
Jan 26, 2025 - 09:45 PM
To properly install and use the legrand KEOR PDU Single Phase UPS, please follow the instructions provided in the instruction manual. Here is a step-by-step guide:
1. Read the entire manual carefully before starting any operation. The manual provides important safety and operating instructions that should always be followed.
2. Ensure that the UPS is used only in residential and commercial environments.
3. Check the guarantee terms and conditions specific to your country. Contact LEGRAND's local sales representative for more information.
4. The manual provides copyright information, stating that the information contained in the manual cannot be disclosed to third parties without written authorization from the Manufacturer.
5. The safety and operating instructions section contains important guidelines that should be followed during installation, use, and maintenance of the UPS. It is recommended to have a qualified electrician install the product.
6. Ensure that the mains supply voltage and frequency match those of the UPS. This information can be found on the product label and in the technical specifications.
7. If any visible damage is found on the product during unpacking, do not install the UPS. Repack the unit and return it to your reseller or distributor.
8. Before operating the UPS or connecting any load equipment, ensure that the UPS is connected to a properly grounded mains socket.
9. The load applied must not exceed the one indicated on the type label of the UPS.
10. The ON/OFF button of the UPS does not electrically isolate the internal parts. To isolate the UPS, unplug it from the mains power socket.
11. Do not attempt to open or disassemble the UPS. There are no user-replaceable parts. Opening the case will void the warranty and introduce the risk of electric shock.
12. Do not plug non-computer-related items such as medical, life-support, and house electric equipment to the UPS output.
13. Do not plug laser printers to the UPS backup outputs due to their high start-up current.
14. The batteries inside the UPS are not user-replaceable. Servicing of batteries must be performed only by electrical hazard-authorized personnel.
15. Follow the cautionary instructions provided for handling batteries, such as removing watches, rings, or other metal objects, using tools with insulated handles, wearing rubber gloves and boots, and not laying tools or metal parts on top of batteries.
16. The UPS has dangerous high voltages on its input and output connections. In case of emergency, immediately turn off the equipment and disconnect the power cord from the AC power supply to disable the UPS.
17. The UPS is intended for indoor installation in a ventilated, controlled indoor environment with a specific temperature and humidity range. Avoid installing the UPS in locations with sparks, smoke, hazardous gas, water, excessive humidity, or dusty, corrosive, and salty environments.
18. Follow the start-up procedure and shutdown instructions provided in the manual.
19. The manual also provides troubleshooting guidelines for common issues that may arise during the use of the UPS.
20. For warehousing and dismantling, follow the instructions provided in the manual. The UPS must be stored in a specific environment, and dismantling and disposal operations should only be done by a qualified electrician.
Please refer to the complete instruction manual for detailed information and specific instructions related to the legrand KEOR PDU Single Phase UPS.