Answer

Jan 26, 2025 - 08:23 PM
To install the Helvar Tracksensor 32xTR, follow these steps:
1. Ensure that all track connectors are positioned inside the unit. Use the levers located at each end of the unit to adjust them accordingly.
2. Make sure that the rib edge of the Tracksensor is on the same side as the allocated groove within the track.
3. Carefully place the adaptor section of the unit into the track, ensuring that the rib is in its allocated groove.
4. On the opposite side of the rib, press the securing lever fully against the underside of the track.
5. Use the locking levers at each end of the adapter to secure the Tracksensor in place. The levers should click and be parallel to the track when fully fitted. Ensure that the Tracksensor sits flush to the track.
For more detailed technical information, refer to the product's datasheets, specifically the 32X Sensor and SBB-X Surface Mounting Box datasheets.
Please note that the Tracksensor only supports DALI tracks, and Helvar takes no responsibility for any track changes made that could affect compatibility. The product is compatible with tested DALI-lighting tracks such as Unipro TC3x, GLOBAL Trac Pulse, and A.A.G. Stucchi ONETRACK®.
If you require further assistance or have any additional questions, you can contact Helvar Ltd at the following:
- Address: Hawley Mill, Hawley Road, Dartford. DA2 7SY. UK
- Website: www.helvar.com
- Phone: +44 (0) 1322 617200
Add New Comment