To adjust the temperature in your Randell PP MNL1712 20000 Series Self-Contained Low Profile Equipment Table, follow these steps:
1. Locate the temperature adjustment control. It is located within the cabinet on the front face of the evaporator coil behind the thermometer. Note that for a 6 drawer unit, you will need to remove the left set of drawers or the center set to access the temperature adjustment control.
2. To lower the temperature, turn the dial xxxx clockwise. There are numbers on the dial to indicate settings. Keep the arrow on the xxxx pointed within the numbered section of the arc. Turning it clockwise beyond the numbered section can result in freeze-up.
3. To raise the temperature, turn the dial xxxx counterclockwise. Again, keep the arrow on the xxxx pointed within the numbered section of the arc. Turning it counterclockwise beyond the numbered section will shut the compressor off.
Note: It is not recommended to turn the dial above 8 or below 1 on the temperature control. If the adjustments still do not result in the proper temperature, please contact the factory at 1-888-994-7636 for further assistance.