To calibrate the Arkscan SF-882 Digital Shipping Scale, please follow the instructions provided in the user manual. Here is a step-by-step guide:
1. Ensure that the scale is placed on a stable and level surface.
2. Power on the scale using the chosen power source (batteries or AC power).
3. Press and hold the Tare button for approximately 3 seconds until the display shows "CAL".
4. Release the Tare button and the display will show "CAL" followed by a number (e.g., CAL 100.0).
5. Place a known weight of a specific value on the scale's platform. The weight should be within the scale's capacity.
6. Press the Tare button again to confirm the calibration weight. The display will show "CAL" followed by a different number (e.g., CAL 100.1).
7. Remove the calibration weight from the platform.
8. The scale is now calibrated and ready for use.
It is recommended to periodically calibrate the scale to ensure accurate measurements. Refer to the user manual for any specific instructions or variations in the calibration process for your model of the Arkscan SF-882 Digital Shipping Scale.