Answer

Jan 18, 2025 - 02:56 AM
To assemble the AVENTICS CL07 single valve with the base plate and valve cover, follow these steps:
1. Mounting the base plate:
- Place the base plate on a flat and firm surface.
- Use the threaded mounting holes on the base plate to secure it to the surface.
2. Positioning the valve and assembling the valve cover:
- Place the valve on the base plate, ensuring that the contacts are straight and the seal is seated correctly.
- Fasten the valve to the base plate using the provided self-tapping screws.
- Set the manual override to position 0.
- Mount the valve cover, making sure the seal is correctly positioned.
- Tighten the hexagon screws on the valve cover.
3. Connecting the pneumatics:
- Ensure that the connection labeled "R" is open and preferably equipped with a silencer.
- Connect the "VENT" connection to a tube that exhausts the air outside the zone or use a silencer if the valve is mounted in a protected area.
- Ensure adequate ventilation through the exhaust air connection and connection "R".
4. Connecting the electrics:
- Make sure the system is not under voltage.
- Insert the cable onto the A-coded M12 round plug connector, ensuring enough free space for the connections.
- Connect solenoid 14 for single solenoid valves. The second control for solenoid 12 remains unused.
Please refer to the AVENTICS CL07 Single Valve Instruction Manual for more detailed instructions and illustrations.