Answer
Jan 18, 2025 - 12:10 AM
Sure! Here is a step-by-step guide on how to install the Altronix NetWay5B 5 Port Hardened Switch:
1. Mount the NetWay5B in the desired location or enclosure using the included mounting hardware.
2. Connect the NetWay5B to a power source and Ethernet devices:
- The NetWay5B can be powered by a UL Listed 12/24VDC power source or an IEEE 802.3at compatible PoE source.
- If using PoE, connect the structured cable from the Ethernet headend device to the RJ45 jack marked [Port 1 PoE Input]. The remaining Ports 2 through 5 are used for data transmission.
- If using a 12/24VDC power source, connect the power source to the [+12/24V -] terminals on the NetWay5B. Then, connect the structured cable from the Ethernet headend device to any RJ45 jack. The remaining RJ45 jacks can be used for connecting Access Control boards, Altronix LINQ units, or other IP devices.
3. Refer to the corresponding Installation Guides for more details on connecting specific devices to the NetWay5B.
Please note that wiring methods should be in accordance with the National Electrical Code/NFPA 70/ANSI and local codes. The NetWay5B should be installed indoors within the protected premises and not connected to outside plant leads.
For more technical specifications and details, please refer to the provided manual.