To select the clock frequency on the PC404A Evaluation Module, you need to move the clock select jumper to the desired position. The clock frequency options are 2 MHz, 1 MHz, and 500 kHz. Refer to Figure 1 in the user guide for the location of the clock select jumper.
To select the integration time, you need to place the jumper at the appropriate location. The integration time is defined by the time between SI clock pulses and can be selected from 128uS to 64mS. Refer to the user guide for the specific jumper locations for different integration time options.
Please note that the user guide provides a table (Table 1) that shows the jumper configurations for different devices. Make sure to refer to this table and set the jumpers accordingly based on the specific device you are using.
Remember to connect an oscilloscope probe to the AO terminal and the scope ground to one of the GND terminals for observing and analyzing the output signals.