Answer
Jan 16, 2025 - 04:03 AM
To install the FlowTron FC 8800 Diplomat Fly Control Device, follow these steps:
1. Determine the placement: Decide whether you will be installing the device indoors or outdoors. For outdoor use, place the unit about 25 feet away from areas intended for human activity. Hang the unit approximately seven feet above the ground. For indoor use, place the device adjacent to entrances, exits, and heavily infested areas.
2. Choose the mounting method: The device can be wall-mounted, ceiling-suspended, or hung from an outdoor bracket or pole. Depending on your chosen method, follow the corresponding assembly instructions provided in the user manual.
- Bracket/Pole Assembly: Remove the hole plug from the center of the top hood. xxxx the threaded xxxx into the hanging ring to create a hanging ring assembly. Thread the ring assembly into the unit through a hole in the center of the top hood.
- Wall Mount Assembly: Remove the hood from the top of the unit. Secure the key-slotted bracket to the top plate using the supplied nuts and bolts. Mount the unit to the wall by installing a #8 steel xxxx into a wall stud and placing the keyhole bracket onto the xxxx .
- Ceiling Suspension Assembly: Remove the hood and collection tray from the unit. Secure the key-slotted brackets to the top plate and base plate using the supplied nuts and bolts. xxxx the threaded nipples into the hanging rings and insert them into a keyhole slot in the bracket. Replace the top hood and collection tray. Suspend the unit from the ceiling using a chain, hooks, or other suitable means.
3. Connect the power: Ensure the unit is disconnected from its power source before proceeding. Use an appropriate three-wire extension cord if needed, following the guidelines provided in the user manual. Plug the power cord into a properly installed and grounded outlet.
4. Maintenance and cleaning: Regularly clean the unit to maintain its effectiveness. Disconnect the unit from its power source before cleaning. Use a small brush, blower, or vacuum cleaner to remove dead insects and debris from the killing grid, bulbs, and glow-tube. Do not spray with water or any other liquid.
By following these installation steps and properly maintaining the device, you can effectively control and eliminate flies using the FlowTron FC 8800 Diplomat Fly Control Device. For more detailed instructions and safety information, refer to the user manual provided with the product.