Answer
Jan 16, 2025 - 02:51 AM
To adjust the ON and OFF times for the pump, you can change the position of the float switch cable in the cable holder. The time interval between pump switch-on and switch-off is adjusted based on the position of the float switch cable. If you want the pump to switch on and off quickly, you can use the "short" float switch cable where the ON and OFF positions are close together. If you want the pump to switch on and off with a longer interval, you can use the "long" float switch cable where the ON and OFF positions are far apart. It is important to ensure that the float switch can move freely to allow the pump to be switched on and off properly.