Answer
Jan 15, 2025 - 12:55 AM
To program and monitor the IFS Single Phase Duplex Capacitor control panel, follow these steps:
1. Locate the touchpad on the inner door of the control panel. This touchpad is used for programming and system monitoring.
2. The touchpad features several buttons and indicators. Here is a description of each:
A. Level Status indicators: These indicators illuminate when floats or set points are activated. An alarm will activate if a float operates out of sequence.
B. HOA (Hand-Off-Automatic) buttons: These buttons control the pump mode and have indication lights. The Hand mode defaults to Automatic when the stop level or redundant off level is reached.
C. Pump Run indicators: These indicators illuminate when pumps are called to run.
D. Lead/Lag selector: This button toggles pump operation between alternate 1-2 and 2-1.
E. LED display: This display provides system information, including the level in inches or centimeters (C-Level™ only), mode, pumps elapsed time, events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), and ON/OFF times (timed dose only).
F. NEXT push button: This button toggles the display to show different information.
G. UP and SET push buttons: These buttons are used to set pump ON/OFF times (timed dose only) and activation levels (C-Level™ only).
3. Use the touchpad to navigate through the different settings and options. The LED display will guide you through the programming and monitoring process.
4. Refer to the panel layout and options listed in the manual to understand the specific configuration and features of your control panel.
Note: The manual provides additional information on the components, options, and pricing of the IFS Single Phase Duplex Capacitor control panel. It is recommended to consult the manual for detailed instructions and specifications.
Add New Comment