Answer

Jan 09, 2025 - 01:55 AM
To calibrate the American Weigh AMW-SHIP330 digital shipping scale, please follow the instructions below:
1. Place the scale on a flat, level surface and ensure it is turned off.
2. Press and hold the MODE key while turning on the scale. The display will show "CAL" followed by a number.
3. Release the MODE key and wait for the display to show "CAL" followed by a different number. This number represents the calibration weight required for calibration.
4. Place the calibration weight on the scale's weighing platform. The display will show "CAL" followed by "PASS" if the calibration is successful.
5. Remove the calibration weight from the platform and turn off the scale.
6. Turn on the scale again to ensure that it is now calibrated correctly.
Please note that the calibration weight required for calibration may vary depending on the specific model of the AMW-SHIP330 scale. It is recommended to refer to the scale's user manual or contact the manufacturer for the exact calibration weight and procedure specific to your scale model.