Answer
Jan 06, 2025 - 05:20 AM
To calibrate the Doran 4302/881, 4300 Checkweigher Scale, follow the steps outlined in the user manual. Here is a step-by-step guide:
1. Ensure that the scale is turned off.
2. Press and hold the "ZERO" button while turning on the scale. Keep holding the button until the display shows "CAL".
3. Release the "ZERO" button. The display will show "CAL 0".
4. Place a known weight on the scale. The weight should be within the scale's capacity and accuracy requirements.
5. Press the "ZERO" button to confirm the weight on the scale as the calibration weight.
6. The display will show "CAL 1".
7. Remove the calibration weight from the scale.
8. The scale will automatically calibrate itself and display "CAL END" when the calibration process is complete.
It is important to note that the calibration process may vary slightly depending on the specific model and firmware version of the Doran 4302/881, 4300 Checkweigher Scale. Therefore, it is recommended to refer to the user manual for the most accurate and up-to-date instructions.
For more detailed information and illustrations, please refer to page 12 of the user manual provided in the link: [Doran 4302/881, 4300 Checkweigher Scale User Manual](https://manuals.plus/wp-content/uploa...)