Answer
Dec 28, 2024 - 11:54 PM
To use the Lisle 28400 Heavy Duty Tester to test a low-voltage circuit, follow these step-by-step instructions:
1. Unpack the Tester: Carefully remove the Lisle 28400 Heavy Duty Tester from its packaging.
2. Check for Damage: Before using the tester, inspect it for any visible damage or flaws.
3. Familiarize Yourself with the Features: Take a close look at the tester's design, including the probe, handle, and cord, to understand how to use it correctly.
4. Connect the Tester: To ensure a stable connection during testing, attach the alligator clip to a good ground point.
5. Insert the Probe: Insert the probe into the part or circuit that you want to test.
6. Check the Voltage Range: For accurate testing, ensure that the voltage of the circuit falls between 0 and 12 volts.
7. Power On (if applicable): If the tester has a power button, switch it on to activate the tester.
8. Monitor the Voltage Readings: Keep an eye on the tester for any numbers that indicate the voltage present in the circuit.
9. Perform Multiple Tests: To familiarize yourself with the tool and its functionality, conduct tests on different parts, such as lights and battery hookups.
10. Disconnect after Testing: Once you have completed the testing, remove the probe and alligator clip from the circuit.
11. Proper Storage: When not in use, store the tester in a safe and secure location.
12. Regular Testing: Test the Lisle 28400 Heavy Duty Tester on known good circuits periodically to ensure its proper functionality.
Please refer to the provided user manual for more detailed instructions and safety precautions.
Add New Comment