Answer
Dec 13, 2024 - 07:41 AM
Calibrating the TireTek TT-GH10-A04-BR2 Heavy Duty Dual Head Tire Gauge is a simple process. Here are the steps to calibrate the gauge:
1. Prepare the gauge: Ensure that the gauge is set to zero and the tire valve is clean.
2. Obtain a known accurate pressure source: To calibrate the gauge, you will need a known accurate pressure source, such as a calibrated air compressor or a certified pressure gauge.
3. Connect the gauge: Attach the appropriate head (straight or angled) of the TireTek TT-GH10-A04-BR2 to the tire valve.
4. Compare readings: Compare the reading on the TireTek gauge to the reading on the known accurate pressure source. If there is a significant difference, the gauge may need calibration.
5. Adjust calibration xxxx : If calibration is required, locate the calibration xxxx on the back of the gauge. Use a small screwdriver to turn the xxxx clockwise to increase the reading or counterclockwise to decrease the reading.
6. Repeat steps 3-5: Repeat steps 3-5 until the gauge reading matches the reading on the known accurate pressure source.
7. Verify accuracy: After calibration, recheck the gauge's accuracy by comparing it to the known accurate pressure source.
Note: It is recommended to have the gauge calibrated annually to ensure ongoing accuracy. If you are unsure about calibrating the gauge yourself, you can contact TireTek customer service for assistance or take it to a professional for calibration.