To install the Leviton 47603-24P 24-Port Structured Media Panel, follow these step-by-step instructions:
1. Position the panel inside the Structured Media Center (SMC) enclosure or remove the plastic mounting hardware and xxxx the panel directly onto a plywood backboard.
2. Align the plastic Push Lock Pins on the distribution panel with the appropriate mounting holes on the enclosure. Seat the panel in place, resting flat against the back of the panel.
3. Press the Push Lock Pins inward with your thumb to lock the panel into place. You will hear a "click" sound when the push locks are secure.
4. Plan your cable routings carefully to ensure the selected distribution panel meets your requirements. Determine the number of outlet locations needed for basic phone, fax, modem, and TV service.
5. The Leviton 47603-24P panel consists of various modules, including the Category 5e Voice and Data Module, Telephone Distribution Module, 1x9 Bridged Telephone Module, and 6-way Video Splitter. Depending on your needs, connect the appropriate modules to the panel.
6. To connect the Category 5e Voice and Data Module, run twisted pair cable from wall outlets to the module. Strip about 3 inches of the outer jacket from the cable and punch individual cable pairs down on the six white connectors on the sides of the module. Match the color coding of the wires to the colors on the connector. Use the plastic tool supplied with the module or a professional-grade termination tool. All four pairs of each cable must be terminated.
7. To connect the Telephone Distribution Module, run twisted pair cable from the telephone company demarcation point to the module. Strip about 3 inches of the outer jacket from the cable and punch individual cable pairs down on the white connector at the top of the module. Each pair of wires corresponds to each line from the phone company. Use a professional-grade termination tool or side cutters to remove excess wire.
8. To connect the 1x9 Bridged Telephone Module, run twisted pair cable from the telephone company demarcation point to the module. Strip 3 inches of the outer jacket from the cable and punch individual cable pairs down on the first white connector at the top of the module. Use the plastic tool supplied with the panel or a professional-grade termination tool. Terminate incoming twisted pair cables onto any of the nine remaining rows of connectors based on the desired phone line at each location.
9. To connect the 6-way Video Splitter, run coaxial cable from incoming cable TV service or a rooftop antenna to the splitter. Attach a male F-type connector onto the incoming cable and xxxx it onto the middle termination point (marked "IN") of the splitter. Terminate the coaxial cables coming from the wall outlets on the other six ports of the splitter.
10. Follow the specific wiring diagrams and instructions provided in the Leviton 47603-24P installation guide for more detailed information on connecting and configuring the modules.
By following these installation steps and referring to the provided wiring diagrams and instructions, you should be able to successfully install the Leviton 47603-24P 24-Port Structured Media Panel in your home.