Sure! Here are the installation requirements and steps for installing the Fanimation FP4640 Wet Location Fan:
Installation Requirements:
1. The fan must be attached to a securely anchored electrical junction box capable of withstanding a load of at least 50 lbs.
2. Requires a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
Installation Steps:
1. Turn off the power to the circuit at the main electrical panel.
2. Remove the existing fan or light fixture from the ceiling.
3. Attach the mounting bracket to the electrical junction box using the provided screws.
4. Connect the fan's wires to the corresponding wires in the electrical junction box: white to white (neutral), black to black (hot), and green or bare copper to the grounding wire.
5. Lift the fan motor assembly and hang it onto the mounting bracket.
6. Secure the fan motor assembly to the mounting bracket using the provided screws.
7. Attach the fan blades to the motor assembly using the provided screws.
8. Install the desired downrod length (optional) by attaching it to the motor assembly.
9. Turn on the power and test the fan to ensure it is working properly.
Please note that these are general installation instructions. For detailed and specific instructions, it is recommended to refer to the Fanimation FP4640 Wet Location Fan User Manual.