To install the Leviton GFWT1-W Weather Tamper-Resistant Receptacle, please follow the provided installation instructions:
1. Turn off the power: Before starting the installation, turn off the power to the circuit at the circuit breaker or fuse box.
2. Remove the existing outlet: If there is an existing outlet, remove it by unscrewing the mounting screws and disconnecting the wires.
3. Prepare the wires: Strip approximately 3/4 inch of insulation from the ends of the wires. If necessary, use wire strippers to do this.
4. Connect the wires: Connect the black (hot) wire to the brass-colored xxxx terminal, the white (neutral) wire to the silver-colored xxxx terminal, and the green or bare copper (ground) wire to the green xxxx terminal. Use the appropriate wire connectors or terminal screws to secure the connections.
5. Mount the receptacle: Align the receptacle with the electrical box and secure it in place using the provided mounting screws. Ensure that the receptacle is level and flush with the wall surface.
6. Restore power: Once the receptacle is securely mounted, turn the power back on at the circuit breaker or fuse box.
Please note that this is a general overview of the installation process. For detailed instructions and specific guidelines, refer to the installation instructions included with the Leviton GFWT1-W Weather Tamper-Resistant Receptacle. If you are unsure about any step or encounter any difficulties during installation, it is recommended to consult a qualified electrician for assistance.