Answer
Oct 31, 2024 - 04:06 AM
Installation of the Pass & Seymour 1597BKCCD12 Radiant Self-Test GFCI Outlet is relatively straightforward. Here are the step-by-step instructions:
1. Turn off the power: Before starting the installation, turn off the power to the circuit at the main electrical panel.
2. Remove the old outlet (if applicable): If you are replacing an existing outlet, carefully remove it from the electrical box by unscrewing the mounting screws and disconnecting the wires.
3. Prepare the wires: Strip about 3/4 inch of insulation from the ends of the black (hot), white (neutral), and green or bare copper (ground) wires.
4. Connect the wires: Connect the black wire to the brass-colored terminal xxxx marked "LINE" on the GFCI outlet. Connect the white wire to the silver-colored terminal xxxx marked "LINE." Connect the green or bare copper wire to the green grounding xxxx .
5. Mount the outlet: Carefully tuck the wires into the electrical box, ensuring they are not pinched or touching each other. Align the GFCI outlet with the mounting holes in the electrical box and secure it with the provided mounting screws.
6. Test the outlet: Turn the power back on at the main electrical panel. Press the "Test" button on the GFCI outlet to verify that it trips and cuts off power. Press the "Reset" button to restore power.
Please note that these instructions are a general guideline, and it is essential to follow the specific instructions provided in the Pass & Seymour 1597BKCCD12 Radiant Self-Test GFCI Outlet's user manual for your safety and to ensure proper installation.