To install the Baomain GFR-20WR-W Tamper-Resistant Outlet Receptacle, please follow these steps:
1. Turn off the power: Before starting the installation, ensure that the power to the electrical circuit is turned off at the circuit breaker or fuse box.
2. Remove the old outlet (if applicable): If you are replacing an existing outlet, carefully remove the old outlet from the electrical box by unscrewing the mounting screws and disconnecting the wires.
3. Prepare the wires: Strip the insulation from the ends of the wires, exposing about 1/2 inch of bare wire. If necessary, consult a qualified electrician for assistance with this step.
4. Connect the wires: Connect the black (hot) wire to the brass-colored xxxx terminal on the receptacle, the white (neutral) wire to the silver-colored xxxx terminal, and the green or bare copper wire to the green xxxx terminal (ground). Use wire connectors or wrap the wires around the screws in a clockwise direction and tighten them securely.
5. Mount the receptacle: Carefully insert the wires into the electrical box, ensuring that the receptacle is properly aligned with the mounting holes. Secure the receptacle to the electrical box using the provided mounting screws.
6. Restore power and test: Once the receptacle is securely mounted, turn the power back on at the circuit breaker or fuse box. Test the receptacle by plugging in a known working device to ensure it is receiving power.
Please note that these instructions are a general guide, and it is important to consult the user manual provided with the Baomain GFR-20WR-W Tamper-Resistant Outlet Receptacle for specific installation instructions and safety guidelines. If you are unsure about any aspect of the installation process, it is recommended to seek assistance from a qualified electrician.