Sure! Here are the step-by-step instructions for installing the Hisense R32 Air Conditioner:
1. Select the installation location for the outdoor unit. Choose a well-ventilated area that is away from flammable gas, direct sunlight, and heat sources. Keep it at a suitable distance from the wall and ensure there is no blockage of the air outlet.
2. Install the drain port and drain hose (for heat-pump models only) to direct the condensate water. Attach the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port.
3. Fix the outdoor unit securely on a flat and strong floor using bolts and nuts. If installing on a wall or roof, make sure to properly fix the supporter to prevent shaking due to vibration or strong wind.
4. Connect the pipes to the 2-way and 3-way valves on the outdoor unit. Make sure to tighten the connections according to the required torque.
5. Connect the power cord to the control board on the outdoor unit. Secure the power cord with a cable clamp.
6. Install an earth leakage circuit breaker in wet or moist areas.
7. Purge the air from the refrigerant cycle using a vacuum pump. Connect the vacuum pump flexible hose to the service valve on the outdoor unit. Start the vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. Close the low-pressure xxxx on the vacuum pump manifold, then stop the vacuum pump. Open the 2-way valve for 10 seconds and then close it. Check the tightness of all joints using liquid soap or an electronic leak detector.
8. Replace and tighten all valve caps.
These are the basic installation steps for the Hisense R32 Air Conditioner. For more detailed instructions and safety precautions, please refer to the instruction manual provided with the product.