Sure! Here are step-by-step instructions on how to light and operate the DEWALT Kerosene Forced-air Heater:
1. Before starting, make sure the heater is placed in a well-ventilated area and away from any flammable materials.
2. Fill the fuel tank with clean kerosene. Use at least 2 gallons of fuel, but do not overfill. Make sure the heater is level.
3. Check for any shipping damage and ensure that all parts are in place and functioning properly.
4. Turn the thermostat to the lowest setting and make sure the "On/Off" switch is in the "Off" position.
5. Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet.
6. Start the heater by pushing the toggle switch to the "On" position. A light will indicate that the switch is in the "On" position.
7. Adjust the thermostat to the desired setting. The heater will cycle on and off as heat is required.
8. In cold weather (below 10 °F [-12.2 °C]), you can improve the starting process by holding a finger over the vent hole of the pump adjustment xxxx cap until the heater starts.
9. If the heater does not start, toggle the switch to the "Off" position, wait 5 minutes, and then toggle it back to the "On" position.
10. To shut down the heater, push the "On/Off" switch to the "Off" position. For extended shutdown, unplug the heater from the power source.
It is important to read and follow all safety precautions and instructions provided in the instruction manual. If you have any further questions or concerns, it is recommended to contact the manufacturer directly for assistance.